Technical Information
Performance
Energy | |
Thermal Insulation – Uf | 2.1 W/m²K |
Comfort | |
Air tightness | Class 4 (600Pa) |
Water tightness | Class 7A (300Pa) |
Wind load resistance | Class C2 (800Pa) |
Acoustics – Rw(C;Ctr) | 42(-1;-4) dB |
Opening & closing resistance | Class 6 |
Safety | |
Burglar resistance | RC2, WK2, RC3, WK3, PAS 24 |
Impact resistance | I5/E5 |
Fire resistance | EI₁ 30, EI₂ 30, EI₂ 60 |
Bullet resistance | FB4, FSG, FB6, Kalashnikov |
Important notice: Performances and properties depend on size, profile combinations, hardware and infill choices. Please contact us for more information.
Properties
Max. dimensions & weight | |||
Max. height of element | 3061 mm | Max. height of vent | 3000 mm |
Min. height of element | 535 mm | Min. width of vent | 500 mm |
Min. width of element | 535 mm | Max. width of vent | 1400 mm |
Max. width of element | 1496 mm | Max. weight of vent | 260 kg |
Min. height of vent | 500 mm | Max. weight of fixed part | 280 kg |
Sightlines | |||
Min. frame width (inward opening) | 68 mm | Min. frame-vent width (outward opening) | 150 mm |
Min. vent width (inward opening) | 76 mm | Min. width T-profile | 76 mm |
Min. frame-vent width (inward opening) | 150 mm | Depth frame | 68 mm |
Min. frame width (outward opening) | 42 mm | Depth Vent | 68 mm |
Min. vent width (outward opening) | 102 mm | Depth frame-vent | 68 mm |
Glazing | |||
Min. glass thickness – frame/element | 4 mm | Max. glass thickness – frame/element | 52 mm |
Min. glass thickness – vent | 4 mm | Max. glass thickness – vent | 52 mm |
Rebate height | 25 mm | ||
Glazing method | Dry glazing, Siliconized glazing, Internal glazing, Glazing bead |
Performance
Energy | |
Thermal Insulation – Uw | Uw Double: 0.3 Btu/hr.ft².°F Uw Triple: 0.31 Btu/hr.ft².°F |
| |
Comfort | |
Air tightness | 0.27 cfm/ft³ |
Water tightness | 3 psf |
AMAA rating | Class CW |
PG rating | 50 |
Acoustics STC | 40 dB |
Acoustics OITC | 36 dB |
Opening & closing resistance | Class 8 |
| |
Safety | |
Burglar resistance | RC2, RC3, PAS 24 |
Fire Resistance | EI₁ 30, EI₂ 30, EI₂ 60, EW 30 |
Impact resistance | I5/E5 |
Bullet resistance | FB4, FSG, FB6, Kalashnikov |
Important notice: Performances and properties depend on size, profile combinations, hardware and infill choices. Please contact us for more information.
Properties
Max. dimensions & weight | |||
Min. height of element | 21 1/16 inch | Max. width of vent | 55 1/8 inch |
Max. height of vent | 118 1/8 inch | Max. weight of vent | 551 lbs |
Min. width of vent | 19 11/16 inch | Max. weight of fixed part | 617 lbs |
| |||
Sightlines | |||
Min. frame width (inward opening) | 2 11/16 inch | Min. frame-vent width (outward opening) | 5 7/8 inch |
Min. vent width (inward opening) | 3 inches | Min. width T-profile | 3 inches |
Min. frame-vent width (inward opening) | 5 7/8 inch | Depth frame | 2 11/16 inch |
Min. frame width (outward opening) | 1 5/8 inch | Depth Vent | 2 11/16 inch |
Min. vent width (outward opening) | 4 inches | Depth frame-vent | 2 11/16 inch |
|
|
|
|
| |||
Glazing | |||
Min. glass thickness – frame/element | 3/16 inch | Max. glass thickness – frame/element | 2 1/16 inch |
Min. glass thickness – vent | 3/16 inch | Max. glass thickness – vent | 2 1/16 inch |
Rebate height | 1 inch | ||
Glazing method | Dry glazing, Siliconized glazing, Internal glazing, Glazing bead |