Technical Information
Performance
Energy |
Thermal Insulation – Uf |
0.79 W/m²K |
|
Comfort |
Air tightness |
Class 4 (600Pa) |
Water tightness |
Class 9A (600Pa) |
Wind load resistance |
Class C3 (1200Pa) |
Important notice: Performances and properties depend on size, profile combinations, hardware and infill choices. Please contact us for more information.
Properties
Max. dimensions & weight |
Min. height of element |
654 mm |
Min. width of vent |
500 mm |
Max. height of element |
3061 mm |
Max. width of vent |
1400 mm |
Min. width of element |
604 mm |
Max. weight of vent |
250 kg |
Max. width of element |
1503 mm |
Max. weight of fixed part |
130 kg |
Min. height of vent |
600 mm |
Max. weight of glass |
1200 kg |
Max. height of vent |
3000 mm |
|
Sightlines |
Min. frame width (inward opening) |
60 mm |
Min. frame-vent width (outward opening) |
145 mm |
Min. vent width (inward opening) |
67 mm |
Min. width T-profile |
87 mm |
Min. frame-vent width (inward opening) |
134 mm |
Depth frame |
97 mm |
Min. frame width (outward opening) |
27 mm |
Depth Vent |
107 mm |
Min. vent width (outward opening) |
118 mm |
Depth frame-vent |
107 mm |
|
Glazing |
Min. glass thickness – frame/element |
20 mm |
Max. glass thickness – frame/element |
78 mm |
Min. glass thickness – vent |
20 mm |
Max. glass thickness – vent |
78 mm |
|
Rebate height |
27 mm |
Glazing method |
Dry glazing, Siliconized glazing, Internal glazing, Glazing bead |