Technical Information
Performance
Energy | |
Thermal Insulation – Uf | 1.7 W/m²K |
Comfort | |
Air tightness | Class 4 (600Pa) |
Water tightness | Class 9A (600Pa) |
Wind load resistance | Class B3 (1200Pa) |
Acoustics – Rw(C;Ctr) | 35(-1;-4) dB – 40(-2;-4) dB |
Opening & closing resistance | Class 3 |
Safety | |
Burglar resistance | RC2, WK2, PAS 24 |
Impact resistance | I4 |
Important notice: Performances and properties depend on size, profile combinations, hardware and infill choices. Please contact us for more information.
Properties
Max. dimensions & weight | |||
Min. height of element | 908 mm | Min. width of vent | 400 mm |
Max. height of element | 2618 mm | Max. width of vent | 1200 mm |
Min. height of vent | 800 mm | Max. weight of vent | 120 kg |
Max. height of vent | 2500 mm | Max. weight of fixed part | 120 kg |
Sightlines | |||
Min. width 4-pane | 134 mm | Depth frame | 68 mm |
Min. width meeting section | 131 mm | Depth Vent | 68 mm |
Min. width T-profile | 30 mm | Depth frame-vent | 68 mm |
Min. height threshold | 15 mm | ||
Glazing | |||
Min. glass thickness – frame/element | 12 mm | Max. glass thickness – frame/element | 55 mm |
Min. glass thickness – vent | 12 mm | Max. glass thickness – vent | 55 mm |
Rebate height | 14 mm | ||
Glazing method | Envelope glazing |