Technical Information
Performance
Energy | |
Thermal Insulation – Uf | 2.25 W/m²K |
Comfort | |
Air tightness | Class 4 (600Pa) |
Water tightness | Class 9A (600Pa) |
Wind load resistance | Class B3 (1200Pa) |
Acoustics – Rw(C;Ctr) | 34(-2;-5) dB – 45(-1;-5) dB |
Opening & closing resistance | Class 3 |
Safety | |
Burglar resistance | RC2, WK2, PAS 24 |
Important notice: Performances and properties depend on size, profile combinations, hardware and infill choices. Please contact us for more information.
Properties
Max. dimensions & weight | |||
Min. height of element | 678 mm | Min. width of vent | 400 mm |
Max. height of element | 3130 mm | Max. width of vent | 1200 mm |
Min. height of vent | 600 mm | Max. weight of vent | 120 kg |
Max. height of vent | 3000 mm | ||
Sightlines | |||
Min. width 4-pane | 154 mm | Depth frame | 77 mm |
Min. width meeting section | 144 mm | Depth Vent | 77 mm |
Min. width T-profile | 48 mm | Depth frame-vent | 77 mm |
Min. height threshold | 5 mm | ||
Glazing | |||
Min. glass thickness – frame/element | 6 mm | Max. glass thickness – frame/element | 63 mm |
Min. glass thickness – vent | 6 mm | Max. glass thickness – vent | 63 mm |
Rebate height | 25 mm | ||
Glazing method | Envelope glazing |