Technical Information
Performance
Energy | |||
Thermal Insulation – Uf | 1.1 W/m²K | Thermal insulation – Uw | 1 W/m²K |
Comfort | |||
Air tightness | Class 4 (600Pa) | ||
Water tightness | Class E750 (750Pa) | ||
Wind load resistance | Class C4 (1600Pa) | ||
Acoustics – Rw(C;Ctr) | 42(-1;-3) dB | ||
Opening & closing resistance | Class 4 | ||
Safety | |||
Burglar resistance | RC2, WK2, PAS 24 | ||
Impact resistance | I5/E5 |
Important notice: Performances and properties depend on size, profile combinations, hardware and infill choices. Please contact us for more information.
Properties
Max. dimensions & weight | |||
Min. height of element | 614 mm | Max. width of vent | 2700 mm |
Max. height of element | 3614 mm | Max. weight of vent | 400 kg |
Min. height of vent | 500 mm | Max. weight of fixed part | 400 kg |
Max. height of vent | 3500 mm | Max. weight of glass | 1500 kg |
Min. width of vent | 700 mm | ||
Sightlines | |||
Min. width 4-pane | 210 mm | Depth Vent | 68 mm |
Min. width meeting section | 50 mm | Depth frame-vent | 155 mm |
Min. width T-profile | 76 mm | Depth frame monorail | 155 mm |
Min. height threshold | 10 mm | Depth frame 2-rail | 155 mm |
Depth frame | 155 mm | Depth frame 3-rail | 242 mm |
Glazing | |||
Min. glass thickness – frame/element | 4 mm | Max. glass thickness – frame/element | 52 mm |
Min. glass thickness – vent | 4 mm | Max. glass thickness – vent | 52 mm |
Rebate height | 25 mm | ||
Glazing method | Dry glazing, Siliconized glazing, Internal glazing, External glazing, Glazing bead, Structural Glued Glazing |
Performance
Energy | |
Thermal Insulation – Uw | Uw Double: 0.34 Btu/hr.ft².°F Uw Triple: 0.28 Btu/hr.ft².°F |
| |
Comfort | |
Air tightness | 0.16 cfm/ft³ |
Water tightness | 12 psf |
AMAA rating | Class AW |
PG rating | 60 |
Acoustics STC | 40 dB |
Acoustics OITC | 35 dB |
Opening & closing resistance | Class 4 |
| |
Safety | |
Burglar resistance | RC2, WK2, PAS 24 |
Impact resistance | I5/E5 |
Important notice: Performances and properties depend on size, profile combinations, hardware and infill choices. Please contact us for more information.
Properties
Max. dimensions & weight | |||
Min. height of element | 24 3/16 inch | Max. width of vent | 106 5/16 inch |
Max. height of element | 142 5/16 inch | Max. weight of vent | 881 lbs |
Min. height of vent | 19 11/16 inch | Max. weight of fixed part | 881 lbs |
Max. height of vent | 137 13/16 inch | Max. weight of glass | 3306 lbs |
Min. width of vent | 27 9/16 inch |
|
|
| |||
Sightlines | |||
Min. width 4-pane | 8 1/4 inch | Depth Vent | 2 11/16 inch |
Min. width meeting section | 1 15/16 inch | Depth frame-vent | 6 1/8 inch |
Min. width T-profile | 3 inches | Depth frame monorail | 6 1/8 inch |
Min. height threshold | 3/8 inch | Depth frame 2-rail | 6 1/8 inch |
Depth frame | 6 1/8 inch | Depth frame 3-rail | 9 1/2 inch |
| |||
Glazing | |||
Min. glass thickness – frame/element | 3/16 inch | Max. glass thickness – frame/element | 2 1/16 inch |
Min. glass thickness – vent | 3/16 inch | Max. glass thickness – vent | 2 1/16 inch |
Rebate height | 1 inch | ||
Glazing method | Dry glazing, Siliconized glazing, Internal glazing, External glazing, Glazing bead, Structural Glued Glazing |