Technical Information
Performance
Energy | |||
Thermal Insulation – Uf | 1.4 W/m²K | Thermal insulation – Uw | 0.8 W/m²K |
Comfort | |||
Air tightness | Class 4 (600Pa) | ||
Water tightness | Class 9A (600Pa) | ||
Wind load resistance | Class C5 (2000Pa) | ||
Acoustics – Rw(C;Ctr) | 41(-1;-4) or 46(-1;-3) dB | ||
Opening & closing resistance | Class 3 | ||
Safety | |||
Burglar resistance | RC2, WK2, PAS 24 |
Important notice: Performances and properties depend on size, profile combinations, hardware and infill choices. Please contact us for more information.
Properties
Max. dimensions & weight | |||
Min. height of element | 1901 mm | Min. width of vent | 1000 mm |
Max. height of element | 4165 mm | Max. width of vent | 3500 mm |
Min. width of element | 2097 mm | Max. weight of vent | 750 kg |
Min. height of vent | 1800 mm | Max. weight of fixed part | 1200 kg |
Max. height of vent | 4000 mm | Max. weight of glass | 1200 kg |
Sightlines | |||
Min. width 4-pane | 67 mm | Depth frame | 148 mm |
Min. width meeting section | 35 mm | Depth Vent | 44 mm |
Min. width T-profile | 35 mm | Depth frame-vent | 148 mm |
Min. visible width (interior view) | 8 mm | Depth frame 2-rail | 148 mm |
Min. visible width (exterior view) | 8 mm | Depth frame 3-rail | 236 mm |
Glazing | |||
Min. glass thickness – frame/element | 36 mm | Max. glass thickness – frame/element | 54 mm |
Min. glass thickness – vent | 36 mm | Max. glass thickness – vent | 54 mm |
Rebate height | 17 mm | ||
Glazing method | Envelope glazing, Structural Glued Glazing |