Technical Information
Performance
Energy |
Thermal Insulation – Uf |
1.3 W/m²K |
Thermal insulation – Uw |
0.8 W/m²K |
|
Comfort |
Air tightness |
Class 4 (600Pa) |
Water tightness |
Class 9A (600Pa) |
Wind load resistance |
Class C5 (2000Pa) |
Acoustics – Rw(C;Ctr) |
44(-1;-4) dB |
Opening & closing resistance |
Class 3 |
|
Safety |
Burglar resistance |
RC2, WK2 |
Impact resistance |
I4 |
Important notice: Performances and properties depend on size, profile combinations, hardware and infill choices. Please contact us for more information.
Properties
Max. dimensions & weight |
Min. height of element |
1906 mm |
Min. width of vent |
700 mm |
Max. height of element |
3706 mm |
Max. width of vent |
3000 mm |
Min. width of element |
1393 mm |
Max. surface of vent |
3600 m2 |
Max. width of element |
3000 mm |
Max. weight of vent |
500 kg |
Min. height of vent |
1800 mm |
Max. weight of fixed part |
400 kg |
Max. height of vent |
3600 mm |
Max. weight of glass |
1200 kg |
|
Sightlines |
Min. width 4-pane |
181 mm |
Depth frame-vent |
180 mm |
Min. width meeting section |
50 mm |
Depth frame monorail |
180 mm |
Min. width T-profile |
80 mm |
Depth frame 2-rail |
180 mm |
Min. visible width (interior view) |
25 mm |
Depth frame 3-rail |
283 mm |
Min. visible width (exterior view) |
15 mm |
Depth frame 4-rail |
180 mm |
Profile design slope |
45 degrees |
Min. depth mullion |
120 mm |
Min. height treshold |
20 mm |
Max. depth transom |
200 mm |
Depth frame |
180 mm |
Min. depth support – horizontal |
50 mm |
Depth Vent |
77 mm |
|
Glazing |
Min. glass thickness – frame/element |
16 mm |
Max. glass thickness – frame/element |
62 mm |
Min. glass thickness – vent |
16 mm |
Max. glass thickness – vent |
62 mm |