Min. vent height |
500 mm |
Max. vent height |
3000 mm |
Min.-max. vent height |
500…3000 mm |
Min. vent width |
500 mm |
Max. vent width |
1200 mm |
Min.-max. vent width |
500…1200 mm |
Vent frame face width |
50 mm |
Min. face width of interlocking section |
112 mm |
Min. system basic depth |
80 mm |
Min.-max. system basic depth |
80…90 mm |
Uw value of window (≥) |
1.3 W/(m²·K) |
Max. sound reduction index Rwp |
47 dB(A) |
Watertightness |
Class 8A |
Burglar resistance |
Up to RC 2 |
Operating type |
manual |
Max. vent weight |
100 kg |
Min. face width |
112 mm |
Max. glass/panel thickness |
53 mm |
Uf value of frame (≥) |
1.7 W/(m²·K) |
Total basic depth |
90 mm |
Width of vent frame |
80 mm |
Max. unit width |
16800 mm |
Max. unit height |
3000 mm |
Outer frame face width |
73 mm |
Min. face width of mullion |
112 mm |
Min.-max. face width of mullion |
112…134.5 mm |
Min. face width of meeting stile |
140 mm |
Min.-max. face width of meeting stile |
140…154.5 mm |
Min.-max. glass/panel thickness |
13…53 mm |
Threshold height |
0 mm, < 12,5 mm, < 20 mm, > 20 mm |
Area of application |
External use, Residential projects |
Shear bond |
Yes |
Meeting stile design |
Yes |
Number of tracks |
Double track |
Track material |
Stainless steel |
Surface finishes |
Powder, Anodized, Paint |
Concealed lock |
Yes |
Fittings installation |
Barrel hinge |
Opening type |
Type 1, Type 2, Type 3, Type 3.1, Type 4, Type 5, Type 6, Type 6/90° |
Air permeability |
Class 3 |
Wind resistance deflection |
Class C2 / B3 |
Wind load resistance |
Class C2 / B3 |
Drainage levels |
3 |
Color-independent |
Yes |